{"product_id":"dmc-dali-dmx512-signal-converter","title":"DMC DALI to DMX512 Signal Converter | Bi-Directional Lighting Protocol Interface","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003e\nThe DMC DALI\/DMX512 Signal Converter is a professional interface device designed to bridge DALI control systems with DMX512 lighting networks. It enables DALI masters to control DMX512 fixtures or DMX decoders with smooth dimming, accurate signal mapping and stable communication performance. Suitable for architectural, commercial, entertainment and smart lighting projects, the DMC simplifies integration between the two most widely used lighting protocols.\n\u003c\/p\u003e\n\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eConverts DALI signals to DMX512 protocol\u003c\/li\u003e\n  \u003cli\u003eAllows DALI controllers to operate DMX512 luminaires and decoders\u003c\/li\u003e\n  \u003cli\u003eSupports DALI DT6 for single-channel dimming applications\u003c\/li\u003e\n  \u003cli\u003eSupports up to 512 DMX channels\u003c\/li\u003e\n  \u003cli\u003eProgrammable channel mapping for precise assignment of DALI addresses to DMX channels\u003c\/li\u003e\n  \u003cli\u003eHigh-speed, stable digital signal output\u003c\/li\u003e\n  \u003cli\u003eSmooth 0–100% dimming with high-resolution data conversion\u003c\/li\u003e\n  \u003cli\u003eMultiple DALI addresses can be mapped to DMX channels for multi-zone or multi-fixture control\u003c\/li\u003e\n  \u003cli\u003eBuilt-in protection for signal integrity and system stability\u003c\/li\u003e\n  \u003cli\u003eCompact housing suitable for control cabinets and junction boxes\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTechnical Notes\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eThe converter works as a bridge: DALI in → DMX512 out.\u003c\/li\u003e\n  \u003cli\u003eEach DALI address can be assigned to one or multiple DMX channels.\u003c\/li\u003e\n  \u003cli\u003eSupports DT6 dimming, allowing smooth control over DMX dimmers, decoders or fixtures.\u003c\/li\u003e\n  \u003cli\u003eUp to 64 DALI addresses may be used depending on system design.\u003c\/li\u003e\n  \u003cli\u003eIdeal for integrating architectural DALI systems with entertainment-grade DMX lighting.\u003c\/li\u003e\n  \u003cli\u003eDMX output follows industry standards for cabling, termination and addressing.\u003c\/li\u003e\n  \u003cli\u003eEnsures stable communication even in long-run DMX installations when properly terminated.\u003c\/li\u003e\n  \u003cli\u003eIncorrect addressing may cause lighting misalignment; always follow your project’s DMX patching plan.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eWiring \u0026amp; Installation Notes\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eConnect DALI bus wires to the DA+ and DA– terminals; ensure a DALI power supply is present.\u003c\/li\u003e\n  \u003cli\u003eConnect the DMX output (D+, D–, GND) to the first DMX fixture or decoder.\u003c\/li\u003e\n  \u003cli\u003eUse proper twisted-pair DMX cable for DMX512 communication.\u003c\/li\u003e\n  \u003cli\u003eTerminate the last DMX fixture with a 120Ω resistor for optimal performance.\u003c\/li\u003e\n  \u003cli\u003eAssign DALI addresses and DMX channels according to the lighting design plan.\u003c\/li\u003e\n  \u003cli\u003eInstall indoors in a dry, ventilated location (IP20 rating).\u003c\/li\u003e\n  \u003cli\u003eFollow DALI and DMX wiring conventions to avoid signal conflicts.\u003c\/li\u003e\n  \u003cli\u003eMount inside a control panel, cabinet or junction enclosure.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIntegrating DALI building control systems with DMX-controlled luminaires\u003c\/li\u003e\n  \u003cli\u003eArchitectural and commercial lighting projects\u003c\/li\u003e\n  \u003cli\u003eRGB, RGBW and multi-channel LED installations via DMX decoders\u003c\/li\u003e\n  \u003cli\u003eBridging automation systems with stage-lighting DMX equipment\u003c\/li\u003e\n  \u003cli\u003eHotels, retail, malls, museums and façade lighting\u003c\/li\u003e\n  \u003cli\u003eAny project requiring protocol conversion between DALI and DMX512\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse;\"\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003cth style=\"text-align:left; padding:8px; border:1px solid #ddd;\"\u003eParameter\u003c\/th\u003e\n      \u003cth style=\"text-align:left; padding:8px; border:1px solid #ddd;\"\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eModel\u003c\/td\u003e\n      \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eDMC DALI\/DMX512 Signal Converter\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eInput Protocol\u003c\/td\u003e\n      \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eDALI (DT6 supported)\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eOutput Protocol\u003c\/td\u003e\n      \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eDMX512 digital signal\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eDMX Output Channels\u003c\/td\u003e\n      \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eUp to 512 channels\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eDimming Range\u003c\/td\u003e\n      \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e0–100% smooth dimming\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eDMX Addressing\u003c\/td\u003e\n      \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eFully programmable channel mapping\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003ePower Supply\u003c\/td\u003e\n      \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eTypically 12–24V DC (depending on version)\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eInstallation\u003c\/td\u003e\n      \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eControl cabinet \/ junction box mount\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eOperating Temperature\u003c\/td\u003e\n      \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e–20°C to +50°C\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eIP Rating\u003c\/td\u003e\n      \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eIP20 (indoor use)\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eDimensions\u003c\/td\u003e\n      \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eCompact, installation-friendly housing\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eWarranty\u003c\/td\u003e\n      \u003ctd style=\"padding:8px, border:1px solid #ddd;\"\u003e5 years\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n","brand":"Luminaria","offers":[{"title":"Default Title","offer_id":45128847229117,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/7379\/8333\/files\/DMC.png?v=1749132560","url":"https:\/\/22halogroup.com\/products\/dmc-dali-dmx512-signal-converter","provider":"Luminaria Lighting","version":"1.0","type":"link"}